Lennox nomenclature model number.

Raider® rooftop units from Lennox Commercial are the new standard for cost efficient reliable, efficient rooftop units built for long-lasting performance that can significantly improve indoor environments. 1. Aluminized Steel Heat Exchanger 2. Scroll Compressors 3. Lennox’ Environ™ Coil System 4. Outdoor Coil Fans 5. Heavy Gauge Steel ...

Lennox nomenclature model number. Things To Know About Lennox nomenclature model number.

MODEL NUMBER IDENTIFICATION ML 1 93 UH 070 X P 36 B Unit Type ML = Merit ® Series Stages 1 = One-Stage Nominal Gas Heat Input Blower 045 = 44,000 Btuh 070 = 66,000 Btuh 090 = 88,000 Btuh 110 = 110,000 Btuh 135 = 132,000 Btuh P = PSC Multi-Speed Blower Motor Nominal Add-On Cooling Capacity 24 = 2 tons 36 = 3 tons 48 = 4 tons 60 = 5 tons ...Model/Part Number 13GCSXA-48-110 Minimum Order Quantity 0.0 Base Unit of Measure EACH EAN / UPC 66255129460 Product Voltage 208/230v 1ph 60 hz Gross Weight. 625 LB. Family. 13GCSX . Cooling Capacity. 4.0 Ton Cooling ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU’s in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU’s. A 2.5 ton system would have 30,000 BTU’s. These are reflected in the model numbers near the middle and often followed by a letter.Raider® rooftop units from Lennox Commercial are the new standard for cost efficient reliable, efficient rooftop units built for long-lasting performance that can significantly improve indoor environments. 1. Aluminized Steel Heat Exchanger 2. Scroll Compressors 3. Lennox’ Environ™ Coil System 4. Outdoor Coil Fans 5. Heavy Gauge Steel ...

SERIAL NUMBER NOMENCLATURE OLD STYLE: 1234-05 99 125 NEW STYLE: A B123-01 14-01 Factory Order Number Or Job Number Month of Manufactured Date Year of Manufactured Date Unit Number of Manufactured Sequence Plant Designation: A = Plant 1 B = Plant 2 Factory Order Number Or Job Number Unit Designation Year of Manufactured Date Month of ...

Lennox AC Age Letter Code For Month of Manufacture Type 3. This type has 2 numbers, a letter, followed by 2 numbers, two letters, and three digits. The first two digits are the day, the letter is the month, and the …In most cases, there's a tag containing the serial number, carrying a label such as "Serial #" or "S/N.". If you can't find the manufacture date on the data plate, the next place to check is inside the electrical control box. Some Lennox air conditioners contain a sticker with the manufacture date on the inside of the control box cover.

tech.lennoxintl.comML195UH. MERIT®SERIES. Upflow / Horizontal. Bulletin No. 210591 March 2019. Supersedes September 2018. AFUE - 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons. MODEL NUMBER IDENTIFICATION. ML 1 95 UH 070 X P 36 B. Unit Type ML = Merit®Series Stages 1 = One-Stage Nominal Gas Heat InputBlower.300 & 360 MODELS “LCA” PACKAGED COOLING & ELECTRIC HEAT “LGA” PACKAGED COOLING & GAS HEAT Net Cooling Capacity – 267,900 to 318,000 Btuh (78.5 to 93.2 …MODEL NUMBER IDENTIFICATION 1.5 to 5 Tons CH23 Horizontal ... • Lennox designed horizontal indoor coils can easily be installed with most Lennox horizontal furnaces • Applicable to expansion valve or RFCIV systems NOTE - Expansion valve systems ... General Data Model No. CH23-21 CH23-31 CH23-41 CH23-51 CH23-65 CH23-68 Nominal size - Tons ...FEATURES. Application. − Provides installation versatility and maximum efficiency in cooling performance, air handling and filtering in cooling or heat pump ap plications. − Available in two model styles, upflow supply air discharge (CB17) or horizontal supply air discharge (CBH17). − Equipped with multi−circuit evaporator coils ...

Lennox stamps the model numbers and essential product details on its nameplate. Except for gas and oil furnaces, where the data plate is located inside the cabinet, near the vestibule panel. All Lennox products display the model number outside the unit. Keep on reading the article to know more about Lennox model numbers and …

Model No. 13CHPA−24 13CHPA−30 13CHPA−36 13CHPA−42 13CHPA−48 13CHPA−60 Data Nominal Tonnage 2 2.5 3 3.5 4 5 Cooling/Heat-i g Cooling Total Capacity − Btuh 24,800 30,000 35,400 40,000 46,000 55,500 ing Performance g Total unit watts 2160 2730 3220 3570 4040 5050 1 SEER (Btuh/Watt) 13.0 13.0 EER (Btuh/Watt) 11.5 11.0 11.0 11.2 11.4 ...

Title: us_ehb_gcs16lg_1193 Author: awh Subject: engineering handbook Created Date: 4/26/2001 3:21:26 PMMulti-Stage Operation. Responding to changing conditions, the 16ACX adjusts to maximize energy savings—operating at lower speed most of the time, and ramping up during periods of increased cooling demand. This multi-stage operation also translates to enhanced humidity control. See How It Works.The following repair parts are available. When ordering parts, include the complete model number and serial number listed on the unit rating plate − e.g. GCS20−024−50−1P HEATING PARTS Heat Exchanger Combustion Air Inducer Assembly Burner Sub−Assembly Combustion Air Orifice Gas Orifices Ignition Electrode Assembly Flame Sensor Burner ...Sit comfortably this Fall with a new desk chair. Staples has numerous models on sale right now through Sept. 10 at up to 60% off. If you need to upgrade the desk chair in your offi...Model Number. 2 Ton / A Standard. KCB/KGB 024S4D/E. 2.5 Ton / A Standard. KCB/KGB 030S4D/E. 3 Ton / A Standard. KCB/KGB 036S4D/E/B. 4 Ton / A Standard. KCB/KGB 048S4D/E/B. 5 Ton / A Standard. KCB/KGB 060S4D/E/B. 6 Ton / A High. KCB/KGB072H4B KCB/KGB074H4T. 6 Ton / A Standard. KCB/KGB074S4T. 7.5 Ton / A Standard. KGB/KCB090S4B KGB/KCB090S4T.

Number of rows 2 3 2 3 3 3 2 Fins per inch 19 14 19 16 14 12 18 Matching Lennox Furnace - Cabinet Width Designation A A B A B A B Coil & Furnace Cabinet Height - in. 14-1/2 14-1/2 17-1/2 14-1/2 17-1/2 14-1/2 17-1/2 Shipping Data - lbs. 44 46 50 56 54 48 49 SPECIFICATIONS 3 TO 5 TON General Data Model No. CHX35 -36C-6F CHX35 -42B-6F CHX35 -42C ...Lennox model number nomenclature - InterNACHI®️ Forum Jul 23, 2016 · Lennox model number nomenclature Specific Inspection Topics Inspecting HVAC Systems sfetty (Dave Fetty, CMI) July 23, 2016, 8:15pm #1 This is a link to a pdf of the Lennox HVAC equipment model number nomenclaturesSo, all of the units that are the same model should also have the same model number. Model numbers are important to the Lennox company, as they signify the age, size, and warranty information for the HVAC unit. ... On the low side, the Lennox 16ACX model has a SEER rating of 14-17. Still, this is average in comparison to other HVAC systems. On ...DAVE LENNOX SIGNATURE® COLLECTION Variable Capacity - Precise Comfort® Technology - 60 Hz Bulletin No. 210813 RESIDENTIAL September 2021 PRODUCT SPECIFICATIONS SL25XPV 2-5 TON HEAT PUMPS * iComfort ® S30 Ultra-Smart Wi-Fi Communicating Thermostat * iComfort® S30 Ultra-Smart Wi-Fi Communicating Thermostat required. Not furnished - Order ...Gas Valve Operation (figures 2 and 3) 1− Set thermostat to lowest setting. 2− Turn off all electrical power to appliance. 3− This furnace is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 4− Open or remove the heat section access panel.Title: us_ehb_gcs16lg_1193 Author: awh Subject: engineering handbook Created Date: 4/26/2001 3:21:26 PM

Model Number KGB092S4B KGB092S4M KGA092H4B KGA092H4M Efficiency Type Standard Standard High High Blower Type CAV (Constant Air Volume) MSAV® (Multi-Stage Air Volume) CAV (Constant Air Volume) MSAV® (Multi-Stage Air Volume) Cooling Performance Gross Cooling Capacity - Btuh 87,800 87,800 93,000 93,000 1 Net Cooling Capacity - Btuh 86,000 86,000 ...2010 Lennox Industries Inc. Dallas, Texas, USA WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life, or ... Model Number Corner Weights Center Of Gravity AA BB CC DD EE FF lbs. lbs. lbs. lbs. in. in. 15GCSXAV−24 74 94 125 97 15.5 28.5

The Lennox CB29M and CB30M Elite. series blower coil. units are designed for installation with a matched remote. outdoor unit and optional field−installed electric heat. The. blower coil units are for indoor installation only. The CB29M and CB30M units, designed for multi−position-. al installations, are completely assembled at the factory.NOTE — Due to Lennox' ongoing committent to quality, Specifications, Ratings and Dimensions subject to change without notice. 1994 Lennox Industries Inc. ... CHA16-413 model requires 2 per unit, LB-82199CF (47J23). CHA16-513-653 models require 3 per unit, LB-82199CG (47J24). Correct number of guards are furnished per order number ...UNCASED AND FULL CASED UP-FLOW EVAPORATOR COILS (Air Conditioning Only) COILS/BLOWER COIL UNITS. ENGINEERING DATA. Nominal Size - 1.5 to 5 Ton (5.3 to 17.6 kW) Typical Application. Utility Room Installation With C23 Uncased Coil, furnace, electronic air cleaner and humidifier. Bulletin No. 210049 April 2000.Model L rooftop units maximize the efficiency of maintenance and service operations, reducing operational costs and minimizing downtime.. The mobile app interface, Lennox CORE Service App, integrates diagnostic, test, and troubleshooting functionalities, reducing install times over traditional built-in interfaces. DirectPlus™ blower standard up …Model/Part Number ZGA092S4B Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255147518 Product Voltage 208/230v 3ph 60 hz Size/Dimensions 49x61x96 Horsepower. 2 . Blower Type or Drive # 1 . Type. Packaged rooftop units ... I DO NOT have a Lennox Customer Number. CONTINUEHi! I'm looking at three very old Mammoth rooftop units. I need to know the tonnage of these units. Is anybody here familiar with the Mammoth nomenclature? Here are the model numbers: DHEBFRC-162-3256-L275-M24 DHEBFRC-171-G256-L275-M25 DHEBFRC-212-G256-L275-M26 Any information would be greatly appreciated!

MODEL NUMBER IDENTIFICATION LGC Y240 S 2 B S 1 Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family ... Lennox was the first HVAC manufacturer to win this award and has been a four−time recipient since 2003. ISO 9001 Registered Manufacturing Quality System.

Hi! I'm looking at three very old Mammoth rooftop units. I need to know the tonnage of these units. Is anybody here familiar with the Mammoth nomenclature? Here are the model numbers: DHEBFRC-162-3256-L275-M24 DHEBFRC-171-G256-L275-M25 DHEBFRC-212-G256-L275-M26 Any information would be greatly appreciated!

Lennox model numbers 14= 1 ton 21= 1-1/2 ton 26= 2 ton 31= 2-1/2 ton 41= 3 ton 46= 3-1/2 ton 51= 4 ton 65= 5 ton So, your unit is a two ton model. The HS stands for high side, HP for heat pump. The next two numbers are the series of unit, they generally work up as they introduce new models. Then a dash and the next two digits which are the ...Application — Lennox GCS20(R)V DX cooling and gas fired all sea-son units are designed for outdoor rooftop or ground level installa-tions in residential or light commercial applications. Units are capa-ble of delivering bottom (down-flo) or side (horizontal) handling of supply and return air. Six model sizes are available, single phaseMODEL NUMBER IDENTIFICATION TGA090 H 2 B S 1 Y Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family T = T−Class Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Nominal Cooling Capacity − Tons 090 = 7.5 Tons 102 = 8.5 Tons 120 = 10 Tons 150 = 12.5 Tons Cooling EfficiencyMODEL NUMBER IDENTIFICATION 1 Indoor coils with the same letter designation will physically match the furnace. AFUE 80 = 80% Low NO x X = Units meet California Nitrogen Oxides Standard (40 ng/J) Cabinet Width A = 14-1/2 in. B = 17-1/2 in. C = 21 in. D = 24-1/2 in. PRODUCT SPECIFICATIONS ML180UH UPFLOW/HORIZONTAL GAS FURNACESOn other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.Brand info that may help determine an age or era. Select one of the drop-down lists below. that corresponds to the 1st letter. of your HVAC brand name. Then make your selection from the Brand Names list. HVAC - A. HVAC - B. HVAC - C. HVAC - D.The Building Intelligence Center assists home inspectors, commercial building inspectors, contractors, service technicians, insurance providers, home owners, and property managers in decoding the age of mechanical appliances such as furnaces, boilers, air conditioners, heat pumps, packaged rooftop units (RTU's), packaged terminal air conditioners (PTAC's), and water heaters.Condensate Drain Heat Cable Kits. − Selflimiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. − Available in 6, 24 or 50 ft. (1.8, 7.3, or 15.2 m) lengths. − See specifications table for order number. Heat Cable Tape: − 66 ft. (20 m) length, 1/2 in. (13 mm) wide fiberglass.Find genuine OEM Lennox GCS24-953-200-1Y replacement parts at Parts Town with the largest in-stock inventory and same day shipping until 9pm ET. ... including Serial Number Lookup, PartSPIN® and Smart Manuals, found on partstown.com and our industry-leading mobile app ... Model: GCS24-953-200-1Y. Manuals Available : 1. Service Manual View ...Dependable Lennox Compressors — Lennox compressors give stag- ing control to fit varying cooling load requirements. 1-953 and GCSI 1-1353 models are equipped with two Lennox series "A" single speed compressors. GCSI 1-1853 model single speed compressors consist of a series "A" and series "D" (10 ton). The GCS 11-2753 has two single speed

MODEL NUMBER IDENTIFICATION K H A 060 S 4 B N 1 Y Brand/Family Voltage K = Landmark® Product Line Unit Type H = Packaged Heat Pump Major Design Sequence A = 1st Generation Nominal Cooling Capacity - Tons 036 = 3 Tons 048 = 4 Tons 060 = 5 Tons 072 = 6 Tons Cooling Efficiency S = Standard Efficiency Refrigerant Type 4 = R-410A Blower TypeSummary of Contents for Lennox KGB Series. Page 1 KGB SERIES 2 to 7-1/2 ton Service Literature 100004 7 to 26 kW May 2020 KGB024 through 090 The KGB packaged gas units are available in standard cooling efficiency (024, 030, 036, 048 060, 072, 074 and 090). Cooling capacities range from 2 to 7-1/2 tons (7 to 26kW).(TXV) and RFC systems. Refer to Lennox engineering handbook for expansion valve kits which must be ordered separately. Shipping & Packing List 1 - Assembled HS29 condensing unit 1-45E copper street elbow 1 - RFCIV refrigerant metering orifice 1 - Coupling, 5/16 x 3/8" (012, 018, 024, 030) Check equipment for shipping damage. If you find anySingle-Stage, 96% Fuel-Efficient Gas Furnace with Power Saver™ Constant-Torque Motor Design. The Power Saver™ constant torque motor in the ML196E uses less energy in both heating and cooling modes, helping you save on utility bills. Flexible airflow based on a home’s ductwork makes this furnace 33% more efficient than older furnaces ...Instagram:https://instagram. veterinarian benson aztexas regional cdl jobsclinton reef lake erie maphow to unghost someone in gta 5 At every turn, the ML296V gas furnace is designed to be the most energy-efficient furnace in its class. A variable-speed fan keeps temperature swings to a bare minimum. Two-stage heating saves gas by adjusting the flame size based on demand. Energy-Efficient Design - With a 96% efficiency rating, the ML296V gas furnace uses 2/3 less energy than ...Lennox Model Number Nomenclature Post World War 2 Ammo Boxes browningmgs com. Valproate sodium C8H15NaO2 PubChem. ... Resources''Lennox Central Air Conditioner Model Number May 6th, 2018 - Continue from Frank s comments Thanks for the great Lennox reviews Frank and here? How to read and decode Your Lennox central air conditioner units''Lennox ... do 100 dollar bills have a blue stripesam's club gas joplin mo Service Literature. G40UH (X) series units are mid−efficiency gas furnaces. used for upflow or horizontal applications only, manufac-. tured with Lennox Duralok Plus heat exchangers formed of. aluminized steel. G40UH (X) units are available in heating. capacities of 44,000 to 154,000 Btuh and cooling applica-. tions up to 5 tons.Cat # : 88M75. Model/Part # : 13ACD-060-230. Product Unavailable. Please call 1-877-570-0123 for more information. Print. Quantity: Add to Cart. Save to List. express times phillipsburg nj obituaries Number and size of filters (in.) Optional Roof Mounting Frame (used with RDE16-41 only) Optional Economizer Dampers Model No. 3 position Modulating Number and size of filters (in.) Optional Ceiling Supply and Return Air Diffusers Step Down Flush Transition 50,000 75,000 38,000 50,000 38,000 75.0%/75.0% 7.8 24,600 2620 10.0 9.4 3 lbs. 3 oz. 9 x ...036, 042, 048, 060 and 072 Models 3 to 6 Ton (10.5 to 21.0 kW) LCA/LGA Bulletin No. 210232 May 1999 Supersedes July 1998 "LCA" Packaged Cooling and Electric Heat