Engtips.

As we lose the stable structure we’re used to, many of us are now experiencing symptoms of burnout. How can we overcome it? Humans are creatures of habit. We function best and feel...

Engtips. Things To Know About Engtips.

Flange face is broken into 3 parts - you have not nominated which part is damaged on your flanges. 1/3 inside the raised face - requires repair if epoxy damaged. 1/3 - the actual Raised Face - does not require epoxy coating. 1/3 - outside the raised face - does not require epoxy coating but if coated with epoxy and …Too much deflection could possibly induce untoward actions on the part of the person falling; if the railing, say, deflected a foot, that might cause the person to try and do something that might cause them additional, or unexpected, harm, as opposed to a railing that only deflected, say, half an inch.JStephen (Mechanical) 13 Feb 17 15:46. If you don't find anything specific to this situation-. Treat the flange as a triangular wedge spreading out at 45 degrees each side from the bolt hole and checking bending at the web. For a one-off design, it may be cheaper to weld a stiffener in than to show it isn't needed.Start with the loaded front wheel loads. The 8000 pounds is presumably the lift capacity and not the total loaded weight. Looking at the contact patch on the loaded front tires will give you a sense of the local punching and beam shear demand-to-capacity ratios.We've been conditioned to tie rewards to travel. But by focusing on rewards beyond travel, we can expand our points and miles freedom. Increased Offer! Hilton No Annual Fee 70K + F...

Boiler and Pressure Vessel engineering. (38965 members) forum794 - Professional forum and technical support for engineers for Boiler and Pressure Vessel engineering. Includes problem solving collaboration tools. Forum. Search.

3 May 05 08:35. An estimate of Young's Modulus for concrete is 57,000 (f'c)^2. For cement grout mixes used in augercast piles (usually 3000 psi to 8000 psi), does anyone know of a similar equation to estimate the elasticity? Based on laboratory testing, elasticity of grout is not anywhere near the elasticity of same strength concrete mixes.

Heat Transfer & Thermodynamics engineering. (36035 members) forum391 - Professional forum and technical support for engineers for Heat Transfer & Thermodynamics engineering. Includes problem solving collaboration tools. Forum.The underlying soils are saturated clayey sand soils (SC). The fill material is a slightly silty sand (-200=12 to 15%) with a modified proctor of 119 pcf and 11% moisture. We have two feet of fill in above the wet clayey soils (SC). The fill material was tested to be at 96 to 98% compaction of the modified proctor …A guide to the most eco-friendly and sustainable luxury hotels in England. The impact that travel has on the planet is causing concern for an increasing number of travelers. Althou...The radius is the larger of the two bones between your elbow and wrist. A Colles fracture is a break in the radius close to the wrist. It was named for the surgeon who first descri...Strength (whether for LRFD or ASD) for wind load is checked at a 700 year MRI for RC2 structures while service load is generally taken to be a 10 year MRI. That can be about 58% less load than the strength check. Service loads are somewhat discretionary...IBC has basic deflection calculation requirements, but they are not the end …

Mar 22, 2023 · From reading XR250s posts I think this is how he approaches it as well. 3. YoungGunner (Structural) 23 Mar 23 15:22. Having worked in residential for 7 years now, I have a few thoughts on the matter: First off, the IRC already shows questionable engineering compared to our "big boy" design standards/codes.

*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Geotechnical Engineers Area. Only the top forums under each heading is …

Mar 2, 2021 · Collaborate with other engineers! Their input will help you overcome mental hurdles and refine your designs. Plus, brainstorming with others is an excellent way to uncover innovative solutions to long-standing engineering issues. A great online resource is eng-tips.com. #13 Over-communicate Stay connected with all the key players in a project. Update: My final solution was to drill and epoxy #3 bars at 24" OC (every 3 CMU courses) with 18" of embedment into the existing walls. However, there was an ice storm in late December that revealed more structural problems with the building only to be exacerbated by the winter storm from February.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Deflections under seismic loading - Part 2. It's my understanding that 4.1.8.11.3) d) v) allows us to use a larger period specifically to check seismic deflections. This means I'll have a different base shear than my regular elastic analysis, so I always run a distinct case anyways.Nigeria’s broadcast regulator, the National Broadcasting Commission, has ordered all broadcasting stations in the country to suspend their use of Twitter. The directive was issued ...

We are designing two building and we have two close columns in between so we are going to design these two columns on one pile cap with one pile. (2columns are 200 kips and 100 kips, clay soil, end bearing 4000 psi, skin friction ignored, Pile Diameter shaft is 3.3ft,bell is 10ft) we can not make it two piles …Heat Transfer & Thermodynamics engineering. (36035 members) forum391 - Professional forum and technical support for engineers for Heat Transfer & Thermodynamics engineering. Includes problem solving collaboration tools. Forum.Three way valve has a one inlet and two outlets. It is not mixing valve. The flow of media through such a valve is through an input and an output. One output is closed. What if the piping of the installation is built in such a way that the second output also receives the media. Physically, the two fluids do not mix because the valve is only ...1st Orifice: Do = 0.51 mm & L = 50 mm ; Pressure drop at Max flow : 6.89 kg/cm2_g. 2nd orifice: Do = 0.51 mm & L = 50.83 mm ; ; Pressure drop at Max flow : 3.44 kg/cm2_g. Data sheet mentions that both are restriction (choke) type venturi. However, when I calculated critical pressure under the given condition to check the whether the … Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Existing 2 storey 40+ yr old house all walls as 4" brick exterior with 4" block backup, with bond bricks turned every 7th course. I believe that this is considered as an 8" masonry bearing wall...not 4" load bearing block with 4" veneer. The building depts around are extremely quick to call out 'brick veneer' can't be used for connecting or ...

We are designing two building and we have two close columns in between so we are going to design these two columns on one pile cap with one pile. (2columns are 200 kips and 100 kips, clay soil, end bearing 4000 psi, skin friction ignored, Pile Diameter shaft is 3.3ft,bell is 10ft) we can not make it two piles …*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Aeronautics & Space Engineers Area. Only the top forums under each …

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book.Pressure/temperature ratings for Class 800 shall be determined by the equation: P8 = 1/3 P6 + 2/3 P9. where. P8 is the pressure at the specified temperature, expressed in bar3, for Class 800 rounded to the nearest. (10 kpa); P6 is the listed pressure, at the specified temperature, for Class 600, expressed in bar;Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net …Civil/Environmental engineering general discussion. (46845 members) forum194 - Professional forum and technical support for engineers for Civil/Environmental engineering general discussion. Includes problem solving collaboration tools. Forum. Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search. HVAC/R engineering. (27384 members) forum403 - Professional forum and technical support for engineers for HVAC/R engineering. Includes problem solving collaboration tools. Search.

Defying stereotypes. At four feet 11 inches, and 73 kilograms, Dolly Singh stands out from the crowd of star yogis on Instagram who have come to be known for their slim waists, mus...

Fluid Power engineering. (8474 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search.

Normally gauges and transmitters come in 1/2 " size. I've not seen many 1/2" flanges used. My standard is to have a flanged isolation valve ,1" often with a 2" tee off the main line and a reducer for mechanical integrity, with a tapped blank flange.11 Oct 10 01:39. In CMAA 74, paragraph 3.3.2.4.2 states: The localized stresses due to local bending effects imposed by wheel loads calculated at points 0 and 1 are to be combined with the stresses due to the Case 2 loading specified in paragraph 3.3.2.3.2 of this specification. However, it does not explicitly state how they should …The Bahamas are a staple on warm-weather cruises. Read on for all you need to know when planning a sailing to the cruise industry's most popular destination. If you've cruised or a...To Remove or insert a Spacer or Blind you first depressurize the System, Then make it Safe. Then you remove all the Bolts on One (1) side of the Flange set. Then you "Jack" the Flanges apart using the built-In Jack Screws (in the Flanges) or with Flange Spreaders (Look it up). Now with the Flanges spread … Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... The kitchen in question is for a residential hall at a college. 2. bookowski (Structural) 17 Feb 13 21:18. Commentary for ASCE7 provides additional occupanies/situations. It lists "Kitchen, other than domestic = 150psf" with a note to use the actual equip. weight if greater. WWTEng (Structural)We are designing two building and we have two close columns in between so we are going to design these two columns on one pile cap with one pile. (2columns are 200 kips and 100 kips, clay soil, end bearing 4000 psi, skin friction ignored, Pile Diameter shaft is 3.3ft,bell is 10ft) we can not make it two piles …hybrid steel/CLT structure. I'm looking to get a better understanding of using CLT deck with gyp concrete topping, supported by steel beams and columns for a five story institutional building. Specifically, what to pay attention to when using the CLT as a floor diaphragm sending lateral forces to concrete shear walls or braced frames for the LFRS.

Wind load on the superstructure may be calculated as. 150 psf x A x L. Where 150 psf is the wind pressure (Check also your state or local requirements for different criteria), A is the area of the superstructure in elevation (Curb height, slab height, haunch height, girder and any superelevation), and L is the tributary length …*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Geotechnical Engineers Area. Only the top forums under each heading is …Wind load on the superstructure may be calculated as. 150 psf x A x L. Where 150 psf is the wind pressure (Check also your state or local requirements for different criteria), A is the area of the superstructure in elevation (Curb height, slab height, haunch height, girder and any superelevation), and L is the tributary length …Instagram:https://instagram. lowes storage racksbealls cc paymentwalgreens deer springs and durangoingredient in vegan marshmallows crossword clue Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search … ups corporate overgoodsapril 2nd weather The current ASME VIII require you to obtain U stamp certification from the ASME Board. They will issue to you, based on extensive testing of your design and fabrication capability, experience and understanding of the current ASME code requirements. No specific PD 5500 requirements. Please note that this month is … mom and sonxxx Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search.Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.